Allen Bradley 1734-OW4 I/O Module - 4 Form A N.O. relays, Digital Contact Output Module Simple Type: PLC

POINT I/O is a family of modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design and operation. As a key element in the Rockwell Automation Integrated Architecture, its comprehensive diagnostics and configurable features allow the product to easily be applied to any automation system and reduce engineering costs through standardization. It can be used in remote device panels, local control panels, and can be accessed from many locations including the Internet. This product is just-what-you-need granularity in one to eight points to reduce system cost and size.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • None Available

Specifications

    General
  • Bounce Time: 1.2ms (mean)
  • Category: 2
  • Conducted RF Immunity: 10Vrms with 1kHz sine-wave 80%AM from 150kHz to 80MHz
  • Conductors Wire Size: 14 AWG (2.5mm2) - 22 AWG (0.25mm2) solid or stranded copper wire rated at 75°C or greater 3/64 inch (1.2mm) insulation maximum
  • Customer load to logic: Tested to withstand 2550V dc for 60s, Tested to withstand 2550V dc for 60s
  • Dimensions Inches: (Millimeters)2.21H x 0.47W x 2.97L(56H x 12W x 75.5L)
  • EFT/B Immunity: ±4kV at 2.5kHz on signal ports, ±4kV at 2.5kHz on power ports
  • Emissions: CISPR 11 Group 1, Class A
  • Enclosure Type Rating: None (open-style)
  • ESD immunity: 6kV contact discharges, 8kV air discharges
  • Expected Life of Electrical Contacts: Minimum 100,000 operations @ rated loads
  • Indicators: 4 yellow output status indicators
  • Initial Contact Resistance: 30m
  • Isolation Voltage: Between any 2 sets of contacts
  • Keyswitch Position: 7
  • Mass: 1.64 oz/46.5 grams
  • Minimum Contact Load: 100µA at 100mV dc
  • Module Location: 1734-TB or -TBS wiring base assembly
  • Off-State Leakage Current (max at 240V ac): 1.2mA and bleed resistor thru snubber circuit]
  • Operate/Release Time: 10ms max
  • Operational Temperature: -20 to 55°C (-4 to 131°F)
  • Output Current Rating (at rated power) Inductive: 2.0A steady state @ 5-28.8V dc, L/R - 7ms
  • Output Current Rating (at rated power)Resistive: 2A @ 5-28.8V dc, 0.5A @ 48V dc, 0.25A @ 125V dc, 2A @ 125V ac, 2A @ 240V ac
  • Output Signal Delay OFF to ON: 10ms maximum (time from valid output on signal to relay
  • Output Signal Delay ON to OFF: 26ms maximum (time from valid output off signal to relay deenergization by module)
  • Output Voltage Range (load dependent): 5-28.8V dc @ 2.0A resistive, 48V dc @ 0.5A resistive, 125V dc @ 0.25A resistive, 125V ac @ 2.0A resistive, 240V ac @ 2.0A resistive
  • Outputs per Module: 4 Form A isolated (normally open) electromechanical relays
  • POINTBus current: 80mA max @ 5V dc
  • Power dissipation: 0.5W max
  • Power Rating (steady state): 250W max. for 125V ac resistive output, 480W max. for 240V ac resistive output, 60W max. for 28.8V dc resistive output, 24W max. for 48V dc resistive output, 31W max. for 125V dc resistive output, 250VA max. for 125V ac inductive output, 480VA max. for 240V ac inductive output, 60VA max. for 28.8V dc inductive output, 24VA max. for 48V dc inductive output, 31VA max. for 125V dc inductive output
  • Radiated RF Immunity: 10V/m with 200Hz 50% Pulse 100%AM at 1890Mhz 10V/m with 200Hz 50% Pulse 100%AM at 900Mhz 10V/m with 1kHz sine-wave 80%AM from 30MHz to 2000MHz
  • Relative Humidity: 5 to 95% noncondensing
  • Shock: operating:30g peak acceleration, Non-operating:50g peak acceleration
  • Storage Temperature: -40 to 85°C (-40 to 185°F)
  • Supply Current: 2A per channel maximum, 8A per module
  • Surge Transient Immunity: ±1kV line-line(DM) and ±2kV line-earth(CM) on power and
  • Switching Frequency: 1 operation/3s (0.3Hz at rated load) max
  • Terminal base screw torque: 7 pound-inches (0.8Nm)
  • Thermal Dissipation: 1.7 BTU/hr max
  • Vibration: Tested 5g @ 10-500Hz
  • Voltage Range: 240V ac max

 

Applications

  • None Available

Aliases